  Sumitube® W3NH
  Dual Wall Polyolefin, 3:1
Operating Temperature: -40 up to 105°C
 

Technical datasheet

Page 1 of 2

 

ASTM
BS 6853
BSS 7239 Boeing Specification Support Standard
Japanese Standard for railway vehicle material
LUL: London Underground Limited Eng. Stand. E 1042. A6
SAE-AMS-DTL-23053

Surface: Matt
Marking: None
 Dimensions
 

BEFORE SHRINKAGE

AFTER SHRINKAGE

DELIVERY UNITS *

Inner diameter (EID) min.

Inner diameter (RID) max. Wall thickness (RWT) min-max Unit quantity Box quantity

[type]

[mm]

[mm] [mm] [m] [m]
3/1 3,20 1,00 nom. 0,95 60 600
4,5/1,5 4,80 1,50 nom. 1,10 60 300
6/2 6,40 2,00 nom. 1,20 60 300
9/3 9,50 3,00 nom. 1,30 30 150
12/4 12,7 4,00 nom. 1,40 30 150
19/6 19,1 6,00 nom. 1,80 18 90
24/8 24,0 8,00 nom. 2,50 18 90
40/13 40,0 13,0 nom. 2,50 6 12
50/19 50,0 19,0 nom. 4,00 2,75 16,5
75/25 75,0 25,0 nom. 3,00 3 24
120/40 120,0 40,0 nom. 3,00 6 36

* Standard packaging: Cut-Lenghts of 1200mm, Lenght of sizes 50/19 = 550 mm and 75/25 = 600mm, LC of size 120/40 = -15% +- 10%
 Colours & Technical drawing

STANDARD COLOURS

black
 
 

SPECIAL COLOURS

upon request
 
 

TECHNICAL DRAWING

Click to enlarge

  © 2009 SUMITOMO ELECTRIC Schrumpf-Produkte GmbH. Subject to change. Tube colours may vary.

SUMITOMO-G-06022012 PM0905



 
  Sumitube® W3NH  
  Dual Wall Polyolefin, 3:1  

 

Technical datasheet

Page 2 of 2

 

 Technical properties

PHYSICAL PROPERTIES

PROPERTY

TEST METHOD REQUIREMENT TYPICAL VALUE
Longitudinal Change SAE-AMS-DTL-23053 -5% ± 10% Pass
Tensile Strength ASTM D 638 Min. 10,4 MPa Pass
Elongation at Break ASTM D 638 Min. 100% Pass
Secant Modulus ASTM D 882 Max. 173 MPa 130 MPa


THERMAL PROPERTIES

PROPERTY

TEST METHOD REQUIREMENT TYPICAL VALUE
Operating Temperature Life-Curve -40 up to 105°C -40 up to 105°C
Min. Shrink Temperature Arrhenius-Plot full recovery 150°C
Shrinking starts at Arrhenius-Plot 60°
Heat Shock (225°C x 4h) SAE-AMS-DTL-23053 no crack, flowing or dripping Pass
Heat Resistance (135°C x 168h) SAE-AMS-DTL-23053 no cracking Pass
Low temperature flexibility (-40°C x 4h) SAE-AMS-DTL-23053 no cracking Pass
Copper Corrosion (121°C x 16h) SAE-AMS-DTL-23053 no corrosion Pass
Colour stability (175°C x 24h) SAE-AMS-DTL-23053 no change Pass


CHEMICAL PROPERTIES

PROPERTY

TEST METHOD REQUIREMENT TYPICAL VALUE
Halogen Content NFX-70-100. BS 6853 Zero Zero
Flammability Japanese Railway flame retardant Pass
Water Absorption ASTM D 570 Max. 1,0% Pass
Flame spread Index ASTM E162 nom. 14 Pass
Flammability-Oxygen Index BS EN ISO 4589-2 part 2 Min. 35% ≥ 37
Flammability Temperature Index NES 715 BS EN ISO 4589-3 Min. 250°C la(300°C) & lb(250°C) > 354°C, Pass
Smoke Emission test BS 6853 / LUL E-M1042 DG > 10 m Pass
Acid Gas Generation (equiv. % of HCL) MIL-C-24643 Max. 0,2% Pass
Toxic Fume Emission LUL E1042 < 0,015 Fully compliant
Toxic gas Generation BSS 7239 Pass


ELECTRICAL PROPERTIES

PROPERTY

TEST METHOD REQUIREMENT TYPICAL VALUE
Voltage Rating 600V Pass
Volume Resistivity ASTM D 876 Min. 1012 Ω·cm > 1013 Ω·cm
Dielectric Strength ASTM D 876 Min. 11,8 kV/mm Pass


OTHER PROPERTIES

PROPERTY

TEST METHOD REQUIREMENT TYPICAL VALUE
Sealing Efficiency SAE-AMS-DTL-23053 no openings on reheat Pass
Fluid Resistance (after immersion 23°C x 24h) ASTM D 638 Min. 4,13 MPa (Tensile Strenght) ≥ 6,7 MPa
Fluid Resistance (after immersion 23°C x 24h) ASTM D 638 Min. 100% (Elongation) ≥ 360%


  © 2009 SUMITOMO ELECTRIC Schrumpf-Produkte GmbH. Subject to change. Tube colours may vary.